Figure 46. ISC Timing
TCK
tISCCH
t ISCCL
t ISCPSU tISCPH
PSD834F2V
TDI/TMS
t ISCPZV
t ISCPCO
ISC OUTPUTS/TDO
tISCPVZ
ISC OUTPUTS/TDO
AI02865
Table 55. Power-down Timing
Symbol
Parameter
tLVDV
ALE Access Time from Power-down
tCLWH
Maximum Delay from APD Enable to
Internal PDN Valid Signal
Note: 1. tCLCL is the period of CLKIN (PD1).
Conditions
Using CLKIN
(PD1)
-10
-15
-20
Unit
Min Max Min Max Min Max
145
150
200 ns
15 * tCLCL1
µs
81/89