B. Detection Length Test
MIM-R1AA38-1
C. Pulse Width Test
θ
Transmitter output
θ
L
Transmitter output
DUT output pulse
600µs 600µs
Vout
D.U.T
θ: indicates horizontal and vertical directions
Twl
Twh
V0h
V0l
CHARACTERISTIC CURVES (TA=25°C)
2.8
2.7
2.6
2.4
2.2
2.0
2
3
4
5
6
7
8
Supply Voltage Vcc (V)
SUPPLY VOLTAGE vs. SUPPLY CURRENT
900
800
Burst length * 600µs, cycle = 1.2ms
tpw: Average value of output from start
700
of signal input to 60th pulse
600
500
Input Level VIN (mVP-P)
400
0.1
1
10
100
1000
Input Level (mVp-p)
INPUT LEVEL vs.OUTPUT PULSE WIDTH
INPUT LEVEL vs.OUTPUT PULSE WIDTH
NOTE 1. Distance between emitter & detector specifies maximum distance that output wave form satisfies
the standard under the conditions below against the standerd transmitter.
(1)Measuring place ………Indoor without extreme reflection of light.
(2)Ambient light source… Detecting surface illumination shall be 200±50Lux under ordinary
hite fluorescense lamp of no high frequency lighting.
(3)Standard transmitter … Burst wave indicated in Fig 1. of standard transmitter
shall be arranged to 50mVp-p under the measuring circuit specified in Fig 2.
Unity Opto Technology Co., Ltd.
07/26/2000
P3