Power-up and power-down
M45PE40
Figure 18.
VCC
VCC(max)
Power-up timing
Program, Erase and Write Commands are Rejected by the Device
Chip Selection Not Allowed
VCC(min)
VWI
Reset State
of the
Device
tVSL
Read Access allowed
tPUW
Device fully
accessible
Table 6. Power-Up timing and VWI threshold
Symbol
Parameter
Min.
tVSL(1) VCC(min) to S low
30
tPUW(1) Time delay before the first Write, Program or Erase instruction
1
VWI(1) Write Inhibit Voltage
1.5
1. These parameters are characterized only, over the temperature range –40°C to +85°C.
time
AI04009C
Max. Unit
µs
10 ms
2.5
V
32/46