M34C02
Table 12. DC Characteristics (M34C02-W)
Symbol
Parameter
Test Condition
(in addition to those in Table 6)
Min.
ILI
Input Leakage Current
(SCL, SDA)
VIN = VSS or VCC
ILO Output Leakage Current
VOUT = VSS or VCC, SDA in Hi-Z
ICC Supply Current
VCC =5V, fc=400kHz (rise/fall time < 30ns)
VCC =2.5V, fc=400kHz (rise/fall time < 30ns)
ICC1 Stand-by Supply Current
VIN = VSS or VCC , VCC = 5V
VIN = VSS or VCC , VCC = 2.5V
Input Low Voltage
VIL (E2, E1, E0, SCL, SDA)
–0.3
Input Low Voltage (WC)
–0.3
VIH
Input High Voltage
(E2, E1, E0, SCL, SDA, WC)
0.7VCC
VOL Output Low Voltage
IOL = 3mA, VCC = 5V
IOL = 2.1mA, VCC = 2.5V
Max. Unit
± 2 µA
± 2 µA
2
mA
1
mA
1
µA
0.5
µA
0.3VCC V
0.5
V
VCC+1 V
0.4
V
0.4
V
Table 13. DC Characteristics (M34C02-L)
Symbol
Parameter
Test Condition
(in addition to those in Table 7)
Min.
ILI
Input Leakage Current
(SCL, SDA)
VIN = VSS or VCC
ILO Output Leakage Current
VOUT = VSS or VCC, SDA in Hi-Z
VCC =5V, fc=400kHz (rise/fall time < 30ns)
ICC Supply Current
VCC =2.5V, fc=400kHz (rise/fall time < 30ns)
VCC =2.2V, fc=400kHz (rise/fall time < 30ns)
ICC1 Stand-by Supply Current
Input Low Voltage
VIL (E2, E1, E0, SCL, SDA)
Input Low Voltage (WC)
VIN = VSS or VCC , VCC = 5 V
VIN = VSS or VCC , 2.2V ≤ VCC < 2.5V
–0.3
–0.3
VIH
Input High Voltage
(E2, E1, E0, SCL, SDA, WC)
0.7VCC
VOL Output Low Voltage
IOL = 3mA, VCC = 5V
IOL = 2.1mA, 2.2V ≤ VCC < 2.5V
Max. Unit
± 2 µA
± 2 µA
2
mA
1
mA
1
mA
1
µA
0.5
µA
0.3VCC V
0.5
V
VCC+1 V
0.4
V
0.4
V
15/26