M27C512
Table 10. Programming Mode DC Characteristics
Symbol
Parameter
Test Condition (1,2)
Min
Max
ILI
Input Leakage Current
VIL ≤ VIN ≤ VIH
±10
ICC
Supply Current
50
IPP
Program Current
E = VIL
50
VIL
Input Low Voltage
–0.3
0.8
VIH
Input High Voltage
2
VCC + 0.5
VOL
Output Low Voltage
IOL = 2.1mA
0.4
VOH
Output High Voltage TTL
IOH = –1mA
3.6
VID
A9 Voltage
11.5
12.5
Note: 1. TA = 25 °C; VCC = 6.25V ± 0.25V; VPP = 12.75V ± 0.25V
2. VCC must be applied simultaneously with or before VPP and removed simultaneously or after VPP.
Unit
µA
mA
mA
V
V
V
V
V
13/22