DC and AC parameters
M25P20
Table 18. AC Characteristics (25MHz Operation, Device Grade 6 or 3)
Test conditions specified in Table 10 and Table 17
Symbol Alt.
Parameter
Min. Typ. Max. Unit
Clock Frequency for the following
fC
fC instructions: FAST_READ, PP, SE, BE,
D.C.
DP, RES, WREN, WRDI, RDSR, WRSR
25
MHz
fR
tCH(1)
tCL(1)
tCLCH(2)
tCHCL(2)
tSLCH
tCHSL
tDVCH
tCHDX
tCHSH
tSHCH
tSHSL
tSHQZ(2)
tCLQV
tCLQX
tHLCH
tCHHH
tHHCH
tCHHL
tHHQX(2)
tHLQZ(2)
tWHSL(4)
tSHWL(4)
tDP(2)
tRES1(2)
tCLH
tCLL
tCSS
tDSU
tDH
tCSH
tDIS
tV
tHO
tLZ
tHZ
Clock Frequency for READ instructions
Clock High Time
Clock Low Time
Clock Rise Time(3) (peak to peak)
Clock Fall Time(3) (peak to peak)
S Active Setup Time (relative to C)
S Not Active Hold Time (relative to C)
Data In Setup Time
Data In Hold Time
S Active Hold Time (relative to C)
S Not Active Setup Time (relative to C)
S Deselect Time
Output Disable Time
Clock Low to Output Valid
Output Hold Time
HOLD Setup Time (relative to C)
HOLD Hold Time (relative to C)
HOLD Setup Time (relative to C)
HOLD Hold Time (relative to C)
HOLD to Output Low-Z
HOLD to Output High-Z
Write Protect Setup Time
Write Protect Hold Time
S High to Deep Power-down Mode
S High to Standby Mode without
Electronic Signature Read
D.C.
18
18
0.1
0.1
10
10
5
5
10
10
100
0
10
10
10
10
20
100
20
MHz
ns
ns
V/ns
V/ns
ns
ns
ns
ns
ns
ns
ns
15
ns
15
ns
ns
ns
ns
ns
ns
15
ns
20
ns
ns
ns
3
µs
3 or 30(5) µs
tRES2(2)
S High to Standby Mode with Electronic
Signature Read
1.8 or 30(5) µs
1. tCH + tCL must be greater than or equal to 1/ fC
2. Value guaranteed by characterization, not 100% tested in production.
3. Expressed as a slew-rate.
4. Only applicable as a constraint for a WRSR instruction when SRWD is set at 1.
5. It is 30µs in devices produced with the “X” process technology (grade 3 devices are only produced using
the “X” process technology). Details of how to find the process letter on the device marking are given in the
Application note AN1995.
40/50