APPENDIX C. FLOW CHARTS
Figure 16. Write to Buffer and Program Flowchart and Pseudo Code
Start
Write to Buffer E8h
Command, Block Address
M58LW032D
Note 1: N+1 is number of Words
to be programmed
Read Status
Register
NO
SR7 = 1
YES
Write N(1),
Block Address
Write Buffer Data,
Start Address
NO
Write to Buffer YES
Timeout
Try Again Later
X=0
Note 2: Next Program Address must
have same A5-A21.
X=N
YES
NO
Write Next Buffer Data,
Next Program Address(2)
X=X+1
Program Buffer to Flash
Confirm D0h
Read Status
Register
NO
SR7 = 1
YES
Note 3: A full Status Register Check must be
done to check the program operation's
success.
Full Status
Register Check(3)
End
AI05511
39/50