CS5376A
10.4 Modulator Data Inputs
The MDATA input expects 1-bit ∆Σ data at a
512 kHz or 256 kHz rate. The input rate is selected
by a bit in the CONFIG register (0x00). By default,
MDATA is expected at 512 kHz.
The MDATA input one’s density is designed for
full scale positive at 86% and full scale negative at
14%, with absolute maximum over-range capabili-
ty to 93% and 7%. These raw ∆Σ inputs are deci-
mated and filtered by the digital filter to create 24-
bit samples at the output rate.
10.5 Modulator Flag Inputs
A high MFLAG input signal indicates the corre-
sponding ∆Σ modulator has become unstable due
to an analog over-range input signal. Once the
over-range signal is reduced, the modulator recov-
ers stability and the MFLAG signal is cleared.
The MFLAG inputs are mapped to status bits in the
SD port, and are associated with each sample when
written. See “Serial Data Port” on page 61 for more
information on the MFLAG error bits in the SD
port status byte.