datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

CS5463-IS View Datasheet(PDF) - Cirrus Logic

Part Name
Description
MFG CO.
CS5463-IS Datasheet PDF : 46 Pages
First Prev 21 22 23 24 25 26 27 28 29 30 Next Last
CS5463
6.1.10 Power Offset Register ( Poff )
Address: 14
MSB
LSB
-(20) 2-1
2-2
2-3
2-4
2-5
2-6
2-7
..... 2-17 2-18 2-19 2-20 2-21 2-22 2-23
Default = 0x000000
Power Offset (Poff) is added to the instantaneous power being accumulated in the Pactive register, and can be
used to offset contributions to the energy result that are caused by undesirable sources of energy that are in-
herent in the system. The value is represented in two's complement notation and in the range of -1.0 Poff < 1.0,
with the binary point to the right of the MSB.
6.1.11 Status Register and Mask Register ( Status , Mask )
Address: 15 (Status Register); 26 (Mask Register)
23
DRDY
15
7
TUP
22
14
IROR
6
TOD
21
13
VROR
5
20
CRDY
12
EOR
4
VOD
19
11
IFAULT
3
IOD
18
10
VSAG
2
LSD
17
IOR
9
1
FUP
16
VOR
8
0
IC
Default = 0x800001 (Status Register), 0x000000 (Mask Register)
The Status Register indicates status within the chip. In normal operation, writing a '1' to a bit will cause the bit
to reset. Writing a '0' to a bit will not change it’s current state.
The Mask Register is used to control the activation of the INT pin. Placing a logic '1' in a Mask bit will allow the
corresponding bit in the Status Register to activate the INT pin when the status bit is asserted.
DRDY
Data Ready. During conversions, this bit will indicate the end of computation cycles. For cali-
brations, this bit indicates the end of a calibration sequence.
CRDY
Conversion Ready. Indicates a new conversion is ready. This will occur at the output word rate.
IOR
Current Out of Range. Set when the Instantaneous Current Register overflows.
VOR
Voltage Out of Range. Set when the Instantaneous Voltage Register overflows.
IROR
VROR
EOR
IFAULT
IRMS Out of Range. Set when the IRMS Register overflows.
VRMS Out of Range. Set when the VRMS Register overflows.
Energy Out of Range. Set when PACTIVE overflows.
Indicates a current fault has occurred. See Section 5.6 Sag and Fault Detect Feature on page
19.
VSAG
Indicates a voltage sag has occurred. See Section 5.6 Sag and Fault Detect Feature on page
19.
TUP
Temperature Updated. Indicates the Temperature Register has updated.
TOD
Modulator oscillation detected on the temperature channel. Set when the modulator oscillates
due to an input above full scale.
VOD (IOD) Modulator oscillation detected on the voltage (current) channel. Set when the modulator oscil-
DS678F2
29

Share Link: 