9.19 Power Control (Address 5Fh)
7
AutoRetry
6
EnOCProt
5
SelectVD
4
PDnADC
3
PDnOut3/4
2
PDnOut2
1
PDnOut1
CS4525
0
PDnAll
9.19.1 Automatic Power Stage Retry (AutoRetry)
Default = 1
Function:
Enables the Auto-Retry function upon over-current error. See “Automatic Power Stage Shut-Down” on
page 53.
AutoRetry Setting
Auto-Retry State
0 .......................................... Auto-Retry feature disabled.
1 .......................................... Auto-Retry feature enabled.
9.19.2 Enable Over-Current Protection (EnOCProt)
Default = 1
Function:
Enables the PWM power output over-current protection feature described in “Automatic Power Stage
Shut-Down” on page 53.
WARNING: The EnOCProt bit must never to changed from its default value of 1. Doing so will disable the over-cur-
rent protection feature and may result in permanent damage to the CS4525.
9.19.3 Select VD Level (SelectVD)
Default = 1
Function:
This bit selects between a VD of 2.5 V, 3.3 V, or 5.0 V.
SelectVD Setting
Selected VD Level
0 .......................................... VD = 2.5 V.
1 .......................................... VD = 3.3 V or 5.0 V.
9.19.4 Power Down ADC (PDnADC)
Default = 1
Function:
The ADC will enter a power down state when this bit is enabled.
PDnADC Setting
ADC Power-Down State
0 .......................................... Normal ADC operation.
1 .......................................... ADC power-down enabled.
88
DS726PP3