datasheetbank_Logo    Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site
Part Number :
Home  >>>  D2S Datasheet

D2S

  

Datasheet PDF

Match, Like N/A
Start with D2S4* D2S6* D2SB* D2SW*
End *MD2S *1D2S *-D2S *6D2S *AD2S *0D2S *RD2S *3D2S *XD2S *SD2S
Included *D2S1* *D2S2* *D2S7* *D2S8* *D2SA* *D2SB* *D2SD* *D2SF* *D2SG* *D2SL* *D2SM* *D2SR* *D2SS* *D2ST* *D2SV*
View Details    
Manufacturer Part no Description View
Panasonic
Panasonic Corporation
TXD2SL-2M-9V-6 High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SL-2M-9V-6 PDF
Panasonic
Panasonic Corporation
TXD2SS-L-12V-6-X High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SS-L-12V-6-X PDF
Panasonic
Panasonic Corporation
TXD2SA-L-H-6V-6-X High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SA-L-H-6V-6-X PDF
Panasonic
Panasonic Corporation
TXD2SS-3V-Z High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SS-3V-Z PDF
Panasonic
Panasonic Corporation
TXD2SS-2M-4.5V-4-Z High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SS-2M-4.5V-4-Z PDF
Panasonic
Panasonic Corporation
TXD2SA-L-2M-H-5V-Z High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SA-L-2M-H-5V-Z PDF
Panasonic
Panasonic Corporation
TXD2SL-L-H-3V-3 High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SL-L-H-3V-3 PDF
Panasonic
Panasonic Corporation
TXD2SA-L-2M-12V-4-Z High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SA-L-2M-12V-4-Z PDF
Panasonic
Panasonic Corporation
TXD2SL-L-2M-H-24V-6 High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SL-L-2M-H-24V-6 PDF
Panasonic
Panasonic Corporation
TXD2SA-H-1.5V-1 High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SA-H-1.5V-1 PDF
Panasonic
Panasonic Corporation
TXD2SA-6V-7-Z High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SA-6V-7-Z PDF
Panasonic
Panasonic Corporation
TXD2SL-L-12V-1-X High breakdown voltage type is available (1.5 kV between open contacts) TX-D RELAYS

FEATURES
1. Lineup now includes high breakdown voltage type that achieves breakdown voltage
   between open contacts of 1,500 VAC.
      Surge breakdown voltage between open contacts:
         1,500 V 10 × 160 µsec. (FCC part 68)
      Surge breakdown voltage between contact and coil:
         6,000 V 1.2 × 50 µsec. (EN60950)
2. Approved to the supplementary insulation class in the EN standards(EN60950).
   The insulation distance between the
   contact and coil meet the
   supplementary insulation class of the
   EN60950 standards as required for
   equipment connected to the telephone
   lines in Europe.
   Satisfies the following conditions:
      • Clearances: 2.0 mm .079 inch or more
      • Creepage distance: 2.5 mm .098 inch or more
3. 3,000 V breakdown voltage between
   contact and coil. (Surge breakdown voltage 6,000 V type)
   The body block construction of the coil
   that is sealed formation offers a high
   breakdown voltage of 3,000 V between
   contact and coil.
4. Nominal operating power:
   High sensitivity of 200mW
   By using the highly efficient polar
   magnetic circuit “seesaw balance
   mechanism”, a nominal operating
   power of 200 mW has been achieved.
5. High contact capacity: 2 A 30 V DC
6. High contact reliability achieved with gold-clad crossbar
   twin contacts and the use of gas expelling materials during formation.
      *We also offer a range of products with
         AgPd contacts suitable for use in low
         level load analog circuits (Max. 10V DC 10 mA).
      *SX relays designed for low level loads are also available.
         (Surge breakdown voltage 2,500 V type only)
7. Outstanding vibration and shock resistance.
   Functional shock resistance: 750 m/s2
   Destructive shock resistance: 1,000 m/s2
   Functional vibration resistance:
      10 to 55 Hz (at double amplitude of 3.3 mm .130 inch)
   Destructive vibration resistance:
      10 to 55 Hz (at double amplitude of 5 mm .197 inch)
8. Sealed construction allows automatic washing.
9. A range of surface-mount types is also available.
   SA: Low-profile surface-mount terminal type
   SL: High connection reliability surface mount terminal type
   SS: Space saving surface-mount terminal type
10. M.B.B. type available (Surge breakdown voltage 2,500 V type only)

TYPICAL APPLICATIONS
1. Facsimile
2. Modem
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security


other parts : TXD2-1.5V  TXD2-1.5V-X  TXD2-1.5V-Z  TXD2-1.5V-1  TXD2-1.5V-1-X  TXD2-1.5V-1-Z  TXD2-1.5V-3  TXD2-1.5V-3-X  TXD2-1.5V-3-Z  TXD2-1.5V-4  
TXD2SL-L-12V-1-X PDF

1

2345678910 Next

New and Popular Datasheet

LM317  PN2222A  1N4007  LM324N  S7010  MB39A108_03  FT5753M  BSS110  2SK2019-01  2SK1279  2SK1277  2SK2050  2SK1507  2SK1507-01M  ESAD83-004  7MBR15SA120D-01  2MBI100NB-120  MMA8451Q  MMZ09312BT1  MPXV7002  MMA7260Q  33975_05  33975_08  ZVNL120A  2SD1351  65239-005LF_  XR21V1412  7MBR35SB120-01  SK3699-01MR  ESAD83-004K  D83-004  2SD1351  7MBR10VKA060-50  XR21V1412IL-0B-EB  NA12W-K  BSS110  ZVNL120A  MPC18730EP  M57184N-715B  M57184N-715B  GZF10C  GZF10C  ESAD83-004R  CA4800C  7MBP150RA060  RY5W-K  PDMB400B12C  MPXV5100GP  MPX5100  MMA7361LC  MC68HC11D3MFN1  MB91232L  MB91F267A  MB91230  TDA2030A  Part List  Manufacturers List 


Key Word
System  Voltage  Analog  Audio  Axial  Battery  Bipolar  Bridge  Camera  Chip  Clock  Color  Connector  Control  Controller  Converter  Counter  Crystal  Decoder  Digital 

@ 2014 - 2018  [ Home ] [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]